Welcome to the official website of Jinan lanjiu Electronic Technology Co., Ltd!

电机驱动器
Your current location : Index >> Products >> Instruments, meters and accessories

Product display Product

Contact usContact Us

Jinan lanjiu Electronic

TEL:13156105039

MAIL:sales@lanjiukeji.com

WEB:www.lanjiukeji.com

WEB:en.lanjiukeji.com

ADD:22 Wuying Shanzhong Road, Huaiyin District, Jinan City, Shandong Province

Timing relay

Timing relay

  • Classification:Instruments, meters and accessories
  • Browse times:times
  • Release date:2019-10-16 09:19:09
  • Product overview
  • Performance characteristics
  • technical parameter

Lk-ysjdq01 series product data

1. Product Name: delay relay

2. Voltage class DC 12V DC 24V AC 110V-220V

3. Time range: 0-999 hour 0-999 minute 0-999 second

4. Display panel size: 79mm * 43mm

5. Installation size: 71mm * 40MM * 24mm

6. Relay: 20A relay, power < 1800W, 1 circuit

7. Wiring instructions:


延时继电器 

 


8. Product instructions:

Before use, first remind the user to pay attention to one point. After setting the data, wait for 6S. After 6S, the module will automatically save the set data.

Press the set key for a short time to enter the time setting mode. The red nixie tube flashes. Adjust the timing time T1 by pressing the key plus or the key minus. Press the set key again after T1 is set. The green nixie tube flashes. Set the timing time T2 by pressing the key plus or the key minus, After T2 time is set, press set key again, the system will automatically save the set time or wait for 6S, and the module will automatically save the data after 6S.

Long press set to enter the parameter setting mode. There are two groups of parameters for users to choose P0 and P1. Press set briefly in the current mode to switch between P0 and P1. Under the P0 parameter, you can set the appropriate timing mode by pressing the key to add or subtract. Under the P1 parameter, you can set the working mode by pressing the key to add or subtract.

P0 -- 0: T1 timing time mode is second

P0-1: T1 timing time mode is minute

P0-2: T1 timing time mode is time

P1 -- 0: relay closing after T1 time delay (T1 timing)

P1-1: relay release after T1 time delay (T1 timing)

P1-2: after T1 time delay, the relay is closed (T1 timing), and then after T2 time delay, the relay is released (T2 timing), and the end.

P1-3: the relay is released after T1 time delay (T1 timing), and then the relay is closed after T2 time delay (T2 timing), and the end.

P1-4: after T1 time delay, the relay is closed (T1 timing), then after T2 time delay, the relay is released (T2 timing), and the cycle is repeated.

P1-5: release the relay after delaying T1 time (T1 timing), then close the relay after delaying T2 time (T2 timing), and repeat the cycle

Example: for example, a customer needs to turn on the machine in 10 seconds, turn off the machine in 20 seconds, and keep cycling. The setting method is as follows:

T1 set time 10, T2 set time 20

P0-0 (T1 timing range is seconds)

P1-5 (timer working mode is to work first and then stop the cycle)

Restore factory settings: due to data disorder caused by wrong press of settings, you can choose to restore factory settings if you cannot. Press and hold set and power on.

Label

Last article:None
Next article:None

Recently browse: